Language:

Professional manufacturer and sales team promise a satisfying cooperation.

Enter keywords to search products

Email: sales@hlcables.com   Service Hotline:+86-371-6676-6667

HOT PRODUCT

  • 600/500V Airport Ligting Cable
    Mobile Concrete Mixing Plant1. Voltage: 600/5000 Voltage; 2. Conductor: Copper; 3.Shield: Cross-linked Polyethlene(XLPE)-5kv; 4Insulated: Cross-linked Polyethlen...
  • MV Aerial bundle cable
    Mobile Concrete Mixing Plant1.Voltage:10kv 33kv,2.support conductor:galvanized steel wire messenger

CONTACT US

  • Tel: +86-371-6676-6667
  • E-mail: sales@hlcables.com
  • Fax:+86-371-8751-3085
  • Msn: WhatsApp:8615093102503

News & Events

yjv32 0.6/1kv 4x16mm2 4x35 4x70 4x95 4x120 4x150 4x185 cu xlpe swa pvc 60502 standard power cable

Information Source:Huadong Cable Group-Zhengzhou Hongliang Cable Co., Ltd24 fiber  Release date:19/06/2017

yjv32 0.6/1kv 4x16mm2  4x35 4x70 4x95 4x120 4x150 4x185 cu xlpe swa pvc 60502 standard power cable.

Product Description

 item name: yjv32 0.6/1kv 4x16mm2  4x35 4x70 4x95 4x120 4x150 4x185 cu xlpe swa pvc 60502 standard power cable.

Cu conductor XLPE insulated PVC sheated steel wire armored power cable  not only have excellent electric, mechanical properties, but also have powerful resistance against chemical corrosion, heataging and environmental stress. Their structures are simple. The permissible maximum operating temperature is 90'C. It is convenient for using, and they can be laid with no restriction of different elevation.

Rate
Voltage(kv)
Sectional
Area(mm 2 )
No.of Core
1st class 0.6/1 1.8/3 3.6/6 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35
1 Core   1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
2 Core   1.5-185 25-185            
3 Core   1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400
4 Core   2.5-400 25-400            
5 Core   2.5-400 25-400            


Type Name Main Application
Cu Core Al Core
YJV
YJY
YJLV
YJLV
XLPE insulated,PVC or PE Sheathed Power Cable For laying indoor,tunnel,channel and undergroud,Unable to bear external mechanical force,but bear the traction force during laid
YJV22
YJV22
YJLV22
YJV22
XLPE Insulated,Steel Tape Armoured,PVC or PE Sheathed Power Cable For laying indoor,tunnel,channel and undergroud Able to bear external mechanical force,but unable to bear large pulling force
YJV32
YJV32
YJLV32
YJLV32
XLPE Insulated,Fine Steel Wire Armoured,PVC or PE Sheathed Power Cable For laying in shaft with large difference of level.Able to bear external machanical force and maderate pulling force
YJV42
YJV42
YJLV42
YJLV42
XLPE Insulated,Thick Steel Wire Armoured,PVC or PE Sheathed Power Cable Able to bear positive pressure and pulling force

Note:"ZR-"Include ABC three kinds of flame retardent cables,which are spectively indicated in "ZRA-" or "ZRB-" "ZRC-".For example:"ZRB-YJV","ZRA-YJV22".

Main Technical Quota
1.DC resistance:conductor resistance of finished cable at 20’C per kilometer is not more than the following values.
Nominal Section
Area(mm 2 )
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Copper Core 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221
Aluminum Core 18.1 12.1 7.41 4.61 3.08 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.778 0.0605 0.0469 0.0367

2.Voltage Test and Partial Discharge Test
Rate
Voltage Uo(kv)
Item
0.6/1 1.8/3 3.6/6 6/6
6/10
8.7/10
8.7/15
12/20 18/20
18/30
21/35 26/35
Voltage Test Voltage 3.5 6.5 12.5 21 30.5 42 63 73.5 91
Test Time 5 5 5 5 5 5 5 5 5
Partial Discharge Test Test Voltage - - 6.2 10.4 15.1 20.8 31.1 36.3

45

Discharge Capacity - - 10 10 10 10 10 10 10
 

Previous | LV AAC conductor triplex XLPE SERVICE Overhead cable ABC ... Next | Quadruplex Service Drop Cable-Aluminum 35mm2, 50mm2, 70mm...