NEWS & EVENTS
HOT PRODUCT
- 600/500V Airport Ligting Cable
1. Voltage: 600/5000 Voltage; 2. Conductor: Copper; 3.Shield: Cross-linked Polyethlene(XLPE)-5kv; 4Insulated: Cross-linked Polyethlen... - MV Aerial bundle cable
1.Voltage:10kv 33kv,2.support conductor:galvanized steel wire messenger
NEWS & EVENTS
- 0.6/1kv Cu 3-4 Core LSF (Flame Fire) PVC/PVC Power Cable
- 120 Volts Single Phase service entrance cable 2x8awg Aluminum SEU Cable price
- Fire proof cable F-FR-8 cable 0.6/1KV Rated voltage cable XLPE insulation FR-PVC sheath Power Cable
- PVC insulation single 25mm2 electric welding cable
- solid copper conductor 2.5mm Flat wire PVC insulated Flexible electric flat cable
- NYY-J PVC 0.6/1kV Power Cable
CONTACT US
- Tel: +86-371-6676-6667
- E-mail: sales@hlcables.com
- Fax:+86-371-8751-3085
- Msn: WhatsApp:8615093102503
News & Events
ICEA S-76-474 Standard Triplex 4/0awg Lepas XLPE insualtion Aerial bundled cable AAAC natural conductor ABC cable
Information Source:Huadong Cable Group-Zhengzhou Hongliang Cable Co., Ltd24 fiber Release date:08/01/2018
ICEA S-76-474 Standard Triplex 4/0awg Lepas XLPE insualtion Aerial bundled cable AAAC natural conductor ABC cable.
Construction:
1. Standard: ICEA S-76-474.
2. Phase conductor: Stranded All Aluminum 1350; AAC.
3. Phase conductor Insulation: XLPE.
4. Neutral conductor: Bare AAC,AAAC,ACSR.
5.The Rated Voltage: 0.6/1KV.
STANDARDS
National : ICEA S-76-474
Desription:
Duplex Overhead Secondary Distribution Cable assemblies consist of one insulated phase conductor and a bare neutral conductor. They are intended for use either as a service drop cable between a power pole and the service entrance, or as a secondary distribution cable between poles. Their use should be limited to circuits not exceeding 600 volts phase-to-phase and a 90°C normal conductor temperature.
Phase Conductor Construction
The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.
Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded
Aluminum alloy 6201-T81, concentric-lay-stranded
Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request.
The XLPE insulation meets the requirements of ANSI/ICEA S-76-474-2004 (Standard for Neutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulation Rated 600 Volts).
The LLDPE insulation meets the requirements of ASTM Standard D1248-05 (Standard Specification for Polyethylene Plastics Molding and Extrusion Materials).
Assembly:
The insulated phase conductor is twisted around the bare neutral conductor with a right-hand lay length of 25 to 60 times the diameter of the phase conductor.
Overhead Secondary Distribution Cable is manufactured and tested in accordance with ANSI/ICEA S-76-474-2004 (Standard for Neutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulation Rated 600 Volts).
Previous | LV 2*16 mm2 AAC conductor Bare Overhard conductor ABC cab... Next | Safty system cable fire resistant cable sillicone insulat...
Related Information:
- duplex cable SHEPHERD AWG #6/7 AAC for Philippines Duplex Cables
- ABC cable 4core X 50mm2 4core x95mm2 Aerial bunded cable 16mm2 XLPE...
- 1000V aluminium phase conductor XLPE insulated 3cx70+1x35sq mm 4cor...
- 6.35/11kV & 12.7/22kV Non Screened ABC Aerial Bundled Cables to AS/...
- ICEA S-76-474 Standard Triplex 4/0awg Lepas XLPE insualtion Aerial ...
- Malaysian standard ABC cable 3x35+35mm2 AAC conductor XLPE insulati...