Language:

Professional manufacturer and sales team promise a satisfying cooperation.

Enter keywords to search products

Email: sales@hlcables.com   Service Hotline:+86-371-6676-6667

HOT PRODUCT

  • 600/500V Airport Ligting Cable
    Mobile Concrete Mixing Plant1. Voltage: 600/5000 Voltage; 2. Conductor: Copper; 3.Shield: Cross-linked Polyethlene(XLPE)-5kv; 4Insulated: Cross-linked Polyethlen...
  • MV Aerial bundle cable
    Mobile Concrete Mixing Plant1.Voltage:10kv 33kv,2.support conductor:galvanized steel wire messenger

CONTACT US

  • Tel: +86-371-6676-6667
  • E-mail: sales@hlcables.com
  • Fax:+86-371-8751-3085
  • Msn: WhatsApp:8615093102503

News & Events

IEC 60502 Water-Resistance XLPE Insulated 11kv ABC cable Overhead AAC ACSR AAAC conductor ABC cable

Information Source:Huadong Cable Group-Zhengzhou Hongliang Cable Co., Ltd24 fiber  Release date:13/10/2018

Description:

ABC Power Cable has an Aluminum Alloy conductor with a XLPE sheath. 
ABC Power Cable usually has 3 cores plus neutral, the neutral can either be bare or insulated and the cable can have a street light of 25mm². 
ABC Power Cable is available in 600/1000V, 635/11kV or 12,7/22kV. We stock 1 core, 2 core and 3 core Aluminum Alloy cable Aerial Bunched Kabel .

Construction:
1.Stranded Aluminum/Aluminum Alloy conductor
2.PE or XLPE insulation
3.ACSR, AAAC,Galvanized steel wire Messenger wire
3 power cores consisting of standard aluminum conductors, insulated with XLPE insulation
+ One sheath lighting aluminum conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)

The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor

 

Construction Parameters              
IEC 60502 6.35/11 kV ABC for Overhead Distribution Lines              
Number of Cores 
x Nominal Cross Section
Phase Conductor Messenger Suspension 
Unit
Continuous current rating at 300C ambient temp
Stranding Nominal Sectional Area Maximum Conductor Resistance Stranding Nominal Sectional Area Breaking Load    
No.×mm^2 No.×mm mm^2 Ω/Km No.×mm mm^2 KN  A
3X50 + 1X25 19/1.78 50 0.641 7/3.0 50 60 116
3X70 + 1X50 19/.14 70 0.443 7/3.15 50 62 210
3X95+ 1X50 19/2.52 95 0.32 7/3.0 50 60 173
3X185+1X120 37/2.52 185 0.164 7/4.67 120 150 259
3X150 +1X50 37/2.25 150 0.206 7/3.15 50 62 365
3X240 +1X50 61/2.25 240 0.125 7/3.15 50 62 500
Other cross-sections can be offered upon request. 

Previous | 450/750V EPR/CPE Sheath Flexible H07RN Rubber Cable Next | 600V AA8000 Aluminum Conductor XLPE insulation PVC Sheath...