NEWS & EVENTS
HOT PRODUCT
- 600/500V Airport Ligting Cable
1. Voltage: 600/5000 Voltage; 2. Conductor: Copper; 3.Shield: Cross-linked Polyethlene(XLPE)-5kv; 4Insulated: Cross-linked Polyethlen... - MV Aerial bundle cable
1.Voltage:10kv 33kv,2.support conductor:galvanized steel wire messenger
NEWS & EVENTS
- 0.6/1kv Cu 3-4 Core LSF (Flame Fire) PVC/PVC Power Cable
- 120 Volts Single Phase service entrance cable 2x8awg Aluminum SEU Cable price
- Fire proof cable F-FR-8 cable 0.6/1KV Rated voltage cable XLPE insulation FR-PVC sheath Power Cable
- PVC insulation single 25mm2 electric welding cable
- solid copper conductor 2.5mm Flat wire PVC insulated Flexible electric flat cable
- NYY-J PVC 0.6/1kV Power Cable
CONTACT US
- Tel: +86-371-6676-6667
- E-mail: sales@hlcables.com
- Fax:+86-371-8751-3085
- Msn: WhatsApp:8615093102503
News & Events
Overhead Conductor 100mm2 ACSR, AAC, AAAC, ACSS/TW, ACCC, AACSR, ACAR, OPGW 1350 hard drawn
Information Source:Huadong Cable Group-Zhengzhou Hongliang Cable Co., Ltd24 fiber Release date:28/09/2016
Specifications
1 IEC, ASTM, DIN, BS standard
2 ISO,CCC,CB certification
3 Response within 12 hours
4 Free Sample
5 Factory direct sale
Brief Introduction:
These conductors are formed by several wires of aluminium and aluminium clad steel, stranded in concentric layers. The wire or wires which form the core, are made of aluminium clad steel (ARAWELD) and the external layer or layers, are of aluminium.Aluminium clad steel core consist normally of 1, 7 or 19 wires. The diameters of aluminium clad steel and aluminium wires can be the same, or different.By varying the relative proportions of aluminium and aluminium clad steel, the required characteristics for any particular application can be reached. A higher U.T.S. can be obtained, by increasing aluminium clad steel content , and a higher current carrying capacity by increasing aluminium content.
Applications:
Overhead transmission and distribution lines Medium, High and Extra High voltage. Specially recommended in corrosive environments or in coastal areas.Used as bare overhead transmission and as primary and secondary distribution cable. ACSR/AW offers strength characteristics similar to ACSR, along with slightly greater ampacity and resistance to corrosion due to aluminum-cladding of the steel core wires.
Producing Process:
• Aluminium melting,continuous casting and rolling.
• Drawing.
• Stranding of aluminium clad steel cores.
• Stranding of aluminium layers.
Installation:
It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by deficiencies in the installation.
Construction:
The center wire or wires are of aluminum-clad steel and the outer layer or layers of aluminium.
Mechanical Advantages:
Depending on the stranding configuration and conductor size, ACSR/AW weighs three- to six-percent less than its ACSR counterpart. This feature is converted into savings in line design and construction costs.
In most cases, the strength-to-weight ratio of ACSR/AW conductors will surpass galvanized or aluminized cores. In fact, standard ACSR conductors having "B" and "C" galvanized or aluminized cores have strength-to-weight ratios which are considerably lower than those of ACSR/AW.
In addition to the above mechanical consideration, the excellent, time-tested fatigue resistance of ACSR/AW has been demonstrated in installations in both marine and industrial environments.
Improved Efficiency:
The lower A.C. resistance of ACSR/AW provides savings to the user in two ways: lower demand costs and lower operating costs. This reduced resistance is related to conductor configuration and to the increased cross-sectional area of aluminum resulting from the substitution of Alumoweld for ordinary galvanized or aluminized core wire.
Two complementary factors operate in ACSR/AW to achieve lower A.C. resistance. First, the thick cladding contributes an extra cross-sectional area of pure aluminum to facilitate current flow. This also raises the ampacity. The second way Alumoweld core wire reduces A.C. resistance is the lowering of magnetic losses. While it has the same diameter as galvanized or aluminum wire, Alumoweld has significantly less steel in its composition than in ordinary galvanized wire, thus lowering magnetic losses.
Package:In coils, wooden drums, steel drums or steel-wooden drums.
Aluminum conductor :AAC
ACSR: Aluminum conductor Steel Reinforced conductor,
AAAC: All Aluminum Alloy
We can supply this conductor according to different recognized standards,such as IEC61089,BS215,ASTM B232,CSA C49,DIN48204,JIS C3110, customer special specification also can be satisfied.
The data sheets below show the most common standards,British standard.
British Sizes BS215
Code name |
Nominal Area |
Stranding&Wire Diameter |
Approx Overall Diameter |
Sectional Area |
Approx Weight |
Breaking Load |
DC Resistance |
|||
Al |
Steel |
Al |
Steel |
Total |
||||||
mm2 |
mm |
mm |
mm |
mm2 |
mm2 |
mm2 |
Kg/km |
KN |
Ohm/km |
|
Squirrel |
20 |
6/2.11 |
1/2.11 |
6.33 |
21.0 |
3.50 |
24.5 |
84.7 |
7.87 |
1.3659 |
Gopher |
25 |
6/2.36 |
1/2.36 |
7.08 |
26.24 |
4.38 |
30.62 |
106 |
9.61 |
1.0930 |
Ferret |
40 |
6/3.00 |
1/3.00 |
9.00 |
42.41 |
7.07 |
49.48 |
172 |
15.20 |
0.6766 |
Rabbit |
50 |
6/3.35 |
1/3.35 |
10.05 |
52.88 |
8.82 |
61.70 |
214 |
18.35 |
0.5426 |
Mink |
60 |
6/3.66 |
1/3.66 |
11.00 |
63.1 |
10.50 |
73.6 |
254.9 |
21.67 |
0.4540 |
Horse |
70 |
12/2.79 |
7/2.79 |
13.95 |
73.37 |
42.83 |
116.20 |
538 |
61.20 |
0.3936 |
Dog |
100 |
6/4.72 |
7/1.57 |
14.15 |
105.00 |
13.50 |
118.50 |
394 |
32.70 |
0.2733 |
Wolf |
150 |
30/2.59 |
7/2.59 |
18.13 |
158.10 |
36.80 |
194.90 |
726 |
69.20 |
0.1828 |
Goat |
300 |
7/3.71 |
7/3.71 |
26.00 |
324.3 |
75.70 |
400.0 |
1488.2 |
135.13 |
0.0891 |
Bison |
350 |
7/3.00 |
7/3.00 |
27.00 |
381.7 |
49.50 |
431.2 |
1442.5 |
121.30 |
0.0758 |
Zebra |
400 |
54/3.18 |
7/3.18 |
28.62 |
428.90 |
55.60 |
484.50 |
1621 |
131.90 |
0.0674 |