Language:

Professional manufacturer and sales team promise a satisfying cooperation.

Enter keywords to search products

Email: sales@hlcables.com   Service Hotline:+86-371-6676-6667

HOT PRODUCT

  • 600/500V Airport Ligting Cable
    Mobile Concrete Mixing Plant1. Voltage: 600/5000 Voltage; 2. Conductor: Copper; 3.Shield: Cross-linked Polyethlene(XLPE)-5kv; 4Insulated: Cross-linked Polyethlen...
  • MV Aerial bundle cable
    Mobile Concrete Mixing Plant1.Voltage:10kv 33kv,2.support conductor:galvanized steel wire messenger

CONTACT US

  • Tel: +86-371-6676-6667
  • E-mail: sales@hlcables.com
  • Fax:+86-371-8751-3085
  • Msn: WhatsApp:8615093102503

News & Events

Armoured marine cable 33kv XLPE SWA submarine underground cable steel wire armoured cable

Information Source:Huadong Cable Group-Zhengzhou Hongliang Cable Co., Ltd24 fiber  Release date:16/11/2016

 

Standard

The products can be produced according to our factory specification which is equivalent to the standard IEC60502.The factory can also design and manufacture special power cable according to the other standards required by the customers.

 

Properties of  PVC Power Cable

1.The long-time permissible working temperature of cable conductive core is not more than 70 degrees.

2.During short circuit (max permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.

 

Properties of XLPE Power Cable

1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.

2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.

3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.

4.Excellent electrical performance, resistance to chemical corrosion.

5.Can stand advisable traction when laid.Can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

 

Nominal Cross-sectional Areas

1.5 mm, 2.5 mm2  ,4 mm, 6 mm, 10 mm2  , 16 mm,25 mm2  , 35 mm, 50 mm2  ,70 mm2  ,

95 mm2  ,120 mm2  ,150 mm,185 mm2  ,240 mm,300 mm  400 mm2  , 500 mm2  ,   630 mm2  , 

800 mm2

 

Production range

Single core cable: from 1.5 mm2  to 800 mm2,

Multi-core cable: from 1.5 mm2 to 400 mm2