Language:

Professional manufacturer and sales team promise a satisfying cooperation.

Enter keywords to search products

Email: sales@hlcables.com   Service Hotline:+86-371-6676-6667

HOT PRODUCT

  • 600/500V Airport Ligting Cable
    Mobile Concrete Mixing Plant1. Voltage: 600/5000 Voltage; 2. Conductor: Copper; 3.Shield: Cross-linked Polyethlene(XLPE)-5kv; 4Insulated: Cross-linked Polyethlen...
  • MV Aerial bundle cable
    Mobile Concrete Mixing Plant1.Voltage:10kv 33kv,2.support conductor:galvanized steel wire messenger

CONTACT US

  • Tel: +86-371-6676-6667
  • E-mail: sales@hlcables.com
  • Fax:+86-371-8751-3085
  • Msn: WhatsApp:8615093102503

News & Events

overhead AAC ABC cable 3+1 core quadruplex 1/0awg aluminum service drop cable

Information Source:Huadong Cable Group-Zhengzhou Hongliang Cable Co., Ltd24 fiber  Release date:23/10/2017

Item name: overhead AAC ABC cable 3+1 core quadruplex 1/0awg aluminum service drop cable

1,0.6/1KV.
2. Conductor: Pure annealed copper or aluminum.
3. Insulation: XLPE/PE/PVC.
4. Cores: 1 C, 2C, 3C, 4C.
5. Nominal Cross-section: 10mm2 to 400mm2.
6. Standard: GB/T 14049-2008 IEC 60502.
7. Max. Operating Temperature: XLPE/PE: 90 °C , PVC : 70 °C .
8. Type: ABC Cable, JKTRYJ, JKLYJ,JKTRY, JKLY, JKLGYJ, JKLGY, JKLYJ/Q, JKLY/Q, JKLGYJ/Q, JKLGY/Q.
9.Packing: Wooden Drum or according to the customer requirement.
10.Remark: The cable can be of flame retardant, fire resistance and other property.

 

Used to supply power,usually from a pole-mounted transformer, to the user's service head where connection to the service entrance.To be used at 600V or less phase to phase and at conductor temperatures not to exceed 75°C for polyethy insulated or 90°C for crosslinked. 
 

overhead AAC ABC cable 3+1 core quadruplex 1/0awg aluminum service drop cable.

16 mm 2 * 2C

( AL7/1.70+PE O.D.7.10) + AL7/1.70 or + AL6/1.70+G1/1.70

16 mm 2 * 4C

3*(AL7/1.70+PE O.D.7.10) + AL7/1.70 or + AL6/1.70+G1/1.70

25 mm 2 * 2C

( AL7/2.12+PE O.D.8.90) + AL7/2.12 or + AL6/2.12+G1/2.12

25 mm 2 * 4C

3*(AL7/2.12+PE O.D.8.90) + AL7/2.12 or + AL6/2.12+G1/2.12

35 mm 2 * 2C

( AL7/2.50+PE O.D.10.0) + AL7/2.50 or + AL6/2.50+G1/2.50

35 mm 2 * 4C

3*(AL7/2.50+PE O.D.10.0) + AL7/2.50 or + AL6/2.50+G1/2.50

50 mm 2 * 2C

( AL19/1.78+PE O.D.11.7) + AL19/1.78

50 mm 2 * 4C

3*(AL19/1.78+PE O.D.11.7) + AL19/1.78

70 mm 2 * 2C

( AL19/2.12+PE O.D.13.5) + AL19/2.12

70 mm 2 * 4C

3*(AL19/2.12+PE O.D.13.5) + AL19/2.12

95 mm 2 * 2C

( AL19/2.50+PE O.D.15.8) + AL19/2.50

95 mm 2 * 4C

3*(AL19/2.50+PE O.D.15.8) + AL19/2.50

Previous | LV PVC insulated PVC sheath fire-resistance control cable Next | overhead twisted cable XLPE insulation aluminum conductor...

Related Information: