Language:

Professional manufacturer and sales team promise a satisfying cooperation.

Enter keywords to search products

Email: sales@hlcables.com   Service Hotline:+86-371-6676-6667

HOT PRODUCT

  • 600/500V Airport Ligting Cable
    Mobile Concrete Mixing Plant1. Voltage: 600/5000 Voltage; 2. Conductor: Copper; 3.Shield: Cross-linked Polyethlene(XLPE)-5kv; 4Insulated: Cross-linked Polyethlen...
  • MV Aerial bundle cable
    Mobile Concrete Mixing Plant1.Voltage:10kv 33kv,2.support conductor:galvanized steel wire messenger

CONTACT US

  • Tel: +86-371-6676-6667
  • E-mail: sales@hlcables.com
  • Fax:+86-371-8751-3085
  • Msn: WhatsApp:8615093102503

News & Events

Copper Conductor Concentric Cable

Information Source:Huadong Cable Group-Zhengzhou Hongliang Cable Co., Ltd24 fiber  Release date:23/08/2016

Copper Conductor Concentric Cable Descripton:

voltage:0.6/1KV    conductor:  copper or aluminum alloy,    insulation:   PVC,   sheath :PVC

1. application: The concentric cable are used in service entrances replacing low voltage bundled copper cables in order to avoid energy robbery. A common way of energy robbery nowadays is using metallic claws, biting the phase and the neutral conductors, allowing the use of electricity without passing through the energy meter. However, the concentric  cable is so constructed that the use of the claws is not possible anymore. Its neutral conductor surrounding the phase like a wire armoring does not allow any contact with the central phase conductor without touching this concentric neutral conductor.

 
2. Construction: soft annealed copper conductor, class 2 stranding, XLPE inner insulation, neutral conductor applied as an armoring of soft annealed copper wires and a XLPE outer insulation.
Identification of the Insulated Conductors:
The identification is made by the color of the insulation material, being:
•Single-phase conductor: black
•Two-phase conductors: black and red
•Three-phase conductors: black, red and white
Max conductor temperatures
90° at continuous service, 130° overloaded and 250° at short-circuit.
 

Copper Conductor Concentric Cable parameter:

IEC 60502-1 IEC 60228 600/1000v

Size (mm2)

Structure Size mm

Copper cable (kg/km)

 

Concuctor

Insulation

Concentric conductor

Outer sheath

 

 

Single wire

Dia.

PVC

Single wire

UV-PVC

 

 

No.

Dia.

 

Thick

No.

Dia.

Thick

Dia.

(kg/km)

10

7

1.35

4.05

1.55

20

0.85

1.4

11.79

301.55

16

7

1.7

5.1

1.55

32

0.85

1.4

12.84

431.7

25

7

2.14

6.42

1.6

29

1.13

1.5

15.02

647.46

16

7

1.7

5.1

1.55

26

1.13

1.4

13.42

244.16

25

7

2.14

6.42

1.6

29

1.13

1.5

15.02

307.3

35

19

1.53

7.65

1.65

27

1.35

1.6

16.99

390.15

 

IEC 60502-1 IEC 60228 600/1000v

Size (mm2)

Structure Size mm

Copper cable (kg/km)

 

Concuctor

Insulation

Concentric conductor

Outer sheath

 

 

Single wire

Dia.

PVC

Single wire

UV-PVC

 

 

No.

Dia.

 

Thick

No.

Dia.

Thick

Dia.

(kg/km)

10

7

1.35

4.05

1.55

20

0.85

1.4

11.79

301.55

16

7

1.7

5.1

1.55

32

0.85

1.4

12.84

431.7

25

7

2.14

6.42

1.6

29

1.13

1.5

15.02

647.46

16

7

1.7

5.1

1.55

26

1.13

1.4

13.42

244.16

25

7

2.14

6.42

1.6

29

1.13

1.5

15.02

307.3

35

19

1.53

7.65

1.65

27

1.35

1.6

16.99

390.15