ICEA Standard Overhead Secondary Distribution Cable

Information Source:Huadong Cable Group-Zhengzhou Hongliang Cable Co., Ltd24 fiber  Release date:24/08/2016

 Feature:

1. Standard: ICEA S-76-474.            2. Phase conductor: Stranded All Aluminum 1350; AAC.        3. Phase conductor Insulation: XLPE.

4. Neutral conductor: Bare AAC,AAAC,ACSR.              5.The Rated Voltage: 0.6/1KV

Description:

Duplex Overhead Secondary Distribution Cable assemblies consist of one insulated phase conductor and a bare neutral conductor.  They are intended for use either as a service drop cable between a power pole and the service entrance, or as a secondary distribution cable between poles.   Their use should be limited to circuits not exceeding 600 volts phase-to-phase and a 90°C normal conductor temperature.

Phase Conductor Construction: The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.

Neutral Conductor Construction

Cable assemblies are available with the following neutral conductors;      Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded

Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded;                 Aluminum alloy 6201-T81, concentric-lay-stranded

Insulation Material

The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)

Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request.

The XLPE insulation meets the requirements of ANSI/ICEA S-76-474-2004 (Standard for Neutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulation Rated 600 Volts).

The LLDPE insulation meets the requirements of  ASTM Standard D1248-05 (Standard Specification for Polyethylene Plastics Molding and Extrusion Materials).

Assembly:

The insulated phase conductor is twisted around the bare neutral conductor with a right-hand lay length of 25 to 60 times the diameter of the phase conductor.